Table of Contents Previous topic Next topic
MICROPROCESSOR INSTRUCTION REFERENCE->XRI
XRI yy Exclusive Or Immediate Data with Accumulator
A <- A 'xor' yy
Flags
S | Set if result -ve, else cleared |
Z | Set if result zero, else cleared |
AC | Cleared |
P | Set if parity even else cleared |
C | Cleared |
No of bytes | Cycles | |
8085 | 8080A | |
2 | 7 | 7 |